国产精品久久久久久_国产超碰人人做人人爽AV_色欲香天天天综合网站_久久国产色AV_牛牛影视亚洲av成人片_牲交欧美兽交欧美

技術(shù)文章您現(xiàn)在的位置:首頁 > 技術(shù)文章 > BECKHOFF倍福模塊經(jīng)銷
BECKHOFF倍福模塊經(jīng)銷
更新時(shí)間:2018-03-21   點(diǎn)擊次數(shù):1210次

上海勇控自動(dòng)化設(shè)備有限公司主營BECKHOFF倍福,PILZ皮爾茲安全繼電器。

德國倍福自動(dòng)化有限公司的總部位于德國威爾市。公司在世界各地設(shè)有分支機(jī)構(gòu),加上的合作伙伴,目前公司業(yè)務(wù)已遍及60多個(gè)國家。
倍福始終以基于PC的自動(dòng)化新技術(shù)作為公司的發(fā)展理念,所生產(chǎn)的工業(yè)電腦、現(xiàn)場(chǎng)總線模塊、驅(qū)動(dòng)產(chǎn)品和TwinCAT控制軟件構(gòu)成了一套完整的、相互兼容的控制系統(tǒng),可為各個(gè)工控領(lǐng)域提供開放式自動(dòng)化系統(tǒng)和完整的解決方案。近20年來,倍福公司的元件和系統(tǒng)解決方案在世界各地得到了廣泛的應(yīng)用。

端子模塊型號(hào)

KL6831Bus TerminalSMI master terminal, LoVo
KL6841Bus TerminalSMI master terminal, 230 V AC
KL6904Bus TerminalTwinSAFE Logic Bus Terminal with 4 digital outputs 24 V DC, 0.5 A
KL8001Bus TerminalPower terminal for Siemens contactor series Sirius 3R
KL8500Bus TerminalPlaceholder module
KL8519Bus Terminal16-channel digital input signal module, 24 V DC, IEC 61131-2, type 3, filter 3.0 ms with manual operation
KL8524Bus Terminal4 x 2-channel digital output module, 24 V DC, 0.5 A with manual operation
KL8528Bus Terminal8-channel digital output module, 24 V DC, 0.5 A with manual operation
KL8548Bus Terminal8-channel analog output module, 0…10 V, 12 bit with manual operation
KL8601Bus TerminalCommunication module for Schneider TeSys model U
KL8610Bus TerminalAdapter terminal for TeSys model U, KL8601
KL9010Bus TerminalBus end terminal
KL9020Bus TerminalTerminal bus extension, end terminal at KL9050
KL9050Bus TerminalTerminal bus extension, coupler terminal from KL9020 or KL9050
KL9060Bus TerminalAdapter terminal for KL8xxx power terminals
KL9070Bus TerminalShield terminal, 8 x shield
KL9080Bus TerminalIsolation terminal
KL9100Bus TerminalPower supply terminal, 24 V DC
KS9100Bus TerminalPower supply terminal, 24 V DC
KL9110Bus TerminalPower supply terminal with diagnostics, 24 V DC

控制器

CX9000-0000Embedded PCBasic CPU module CX9000, 16 Mbyte Flash/64 Mbyte RAM, E-bus, no TwinCAT
CX9000-0001Embedded PCBasic CPU module CX9000, 16 Mbyte Flash/64 Mbyte RAM, E-bus, TwinCAT 2 PLC run-time
CX9001-0000Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, E-bus, no TwinCAT
CX9001-0001Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, E-bus, TwinCAT 2 PLC run-time
CX9001-0100Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, DVI/USB, E-bus, no TwinCAT
CX9001-0101Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, DVI/USB, E-bus, TwinCAT 2 PLC run-time
CX9000-1000Embedded PCBasic CPU module CX9000, 16 Mbyte Flash/64 Mbyte RAM, K-bus, no TwinCAT
CX9000-1001Embedded PCBasic CPU module CX9000, 16 Mbyte Flash/64 Mbyte RAM, K-bus, TwinCAT 2 PLC run-time
CX9001-1000Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, K-bus, no TwinCAT
CX9001-1001Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, K-bus, TwinCAT 2 PLC run-time
CX9001-1100Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, DVI/USB, K-bus, no TwinCAT
CX9001-1101Embedded PCBasic CPU module CX9000, 32 Mbyte Flash/128 Mbyte RAM, DVI/USB, K-bus, TwinCAT 2 PLC run-time
CX1900-0102Embedded PCSpare battery suitable for CX10x0, CX50x0, CX51x0, CX90x0, CX20x0
– lithium button cell type CR2032, 3V/225 mAh
– follow polarity when installing
CX9000-N010Embedded PCInterface module for DVI+USB connection
– 2D graphics controller: min. resolution 320 x 240, max. 1280 x 1024 (Beckhoff 19" panels)
– standard DVI connector (max. 5...7 m cable length, resolution dependant)
– DVI connector includes VGA signals
  (simple adaptor connects to desktop standard CRT-VGA monitors)
– 2 x USB 2.0 ports type A
– pre-assembled ex factory, cannot be upgraded
– protection class IP 20
– operating/storage temperature: 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 80 g
– dimensions (W x H x D) 19 x 100 x 51 mm
CX9000-N030Embedded PCInterface module for 2 x RS232 connections (COM1 + COM2)
– full 115 kbaud on both channels
– electrically isolated interfaces (optically isolated)
– COM1: RXD, TXD, RTS, CTS
– COM2: RXD, TXD, RTS, CTS
– pre-assembled ex factory, cannot be upgraded
– protection class IP 20
– operating/storage temperature: 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 80 g
– dimensions (W x H x D) 19 x 100 x 51 mm
CX9000-N031Embedded PCInterface module for 2 x RS422/RS485 connections optically isolated (COM1 + COM2)
– full 115 kbaud on both channels
– electrically isolated interfaces (optically isolated)
– modes: RS485: with/without echo, with/without termination, RS422: full duplex
– COM1: RXD, TXD, RTS, CTS
– COM2: RXD, TXD, RTS, CTS
– may not be used at the same time with CX9000-N030
– pre-assembled ex factory, cannot be upgraded
– protection class IP 20
– operating/storage temperature: 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 80 g
– dimensions (W x H x D) 19 x 100 x 51 mm
CX9000-N070Embedded PCExtension module for 4 USB ports
– 4 x USB 2.0 ports type A, current output max. 500 mA
– suppports USB 1.1 and USB 2.0 standard
– transfer rates: 1.5 Mbit/s, 12 Mbit/s and 480 Mbit/s
– for field assembly
– protection class IP 20
– operating/storage temperature: 0°C ... +55°C/-25°C ... +85°C
– weight: ca. 80 g
– dimensions (W x H x D): 19 x 100 x 51 mm
CX9000-A001Embedded PCExtension module for usage of a mass storage Compact Flash card
– Compact Flash card slot for cards type I and II
– front LED indicators for: PWR (power), LOCK (card inserted) and CF (access)
– protection class IP 20
– operating/storage temperature: 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 80 g (without CF card)
– dimensions (W x H x D) 19 x 100 x 51 mm
CX9010Embedded PCModular DIN rail Industrial PC
– 533 MHz In® IXP420 CPU with XScale® technology
– 32 MB internal flash memory (bootable, not expandable)
– 128 MB internal RAM (not expandable)
– 128 kb non-volatile RAM (NOVRAM)
– clock: internal battery-backed clock for time and date, exchangeable battery
– two RJ45 Ethernet connector 10/100 Mbit (integrated switch)
– diagnostics LED: Power, LAN1 Link/Act, LAN2 Link/Act,
   K-bus Run/Err resp. L/A (EtherCAT Link/Act), and HDD access
– I/O interface: K-bus or E-bus
– operating system: Microsoft Windows CE
– max. power loss: 7 W (including CX901x-xxxx system interfaces)
– protection class IP 20
– operating/storage temperature 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 250 g
– dimensions (W x H x D) 59 x 100 x 91 mm

– 'U' = placeholder for the direct I/O interface type:
                0 =       on-board E-bus (Beckhoff EtherCAT Bus Terminals) interface
                1 =       on-board K-bus (Beckhoff Bus Terminals) interface


– 'C' = placeholder for the system interface connector options:
            0 =  preequipped with CX9010-N000 = 2 x Ethernet RJ45 connector (internal switch) + battery compartment
            1 =  preequipped with CX9010-N000 = 2 x Ethernet RJ45 connector (internal switch) + battery compartment
                                             + CX9010-N010 = DVI connector and 2 x USB port connectors


– 'T' = placeholder for the TwinCAT software level options:
                0 =        no TwinCAT software installed
                1 =        preequipped with TwinCAT 2 PLC licence
                2 =        preequipped with TwinCAT 2 NC licence
      

Please refer to the following table listing for the order numbers of the various valid combinations.
 
CX9010-0000Embedded PCBasic CPU module CX9010, E-bus, no TwinCAT
CX9010-0001Embedded PCBasic CPU module CX9010, E-bus, TwinCAT 2 PLC run-time
CX9010-0002Embedded PCBasic CPU module CX9010, E-bus, TwinCAT 2 NC run-time
CX9010-0100Embedded PCBasic CPU module CX9010, DVI/USB, E-bus, no TwinCAT
CX9010-0101Embedded PCBasic CPU module CX9010, DVI/USB, E-bus, TwinCAT 2 PLC run-time
CX9010-0102Embedded PCBasic CPU module CX9010, DVI/USB, E-bus, TwinCAT 2 NC run-time
CX9010-1000Embedded PCBasic CPU module CX9010, K-bus, no TwinCAT
CX9010-1001Embedded PCBasic CPU module CX9010, K-bus, TwinCAT 2 PLC run-time
CX9010-1002Embedded PCBasic CPU module CX9010, K-bus, TwinCAT 2 NC run-time
CX9010-1100Embedded PCBasic CPU module CX9010, DVI/USB, K-bus, no TwinCAT
CX9010-1101Embedded PCBasic CPU module CX9010, DVI/USB, K-bus, TwinCAT 2 PLC run-time
CX9010-1102Embedded PCBasic CPU module CX9010, DVI/USB, K-bus, TwinCAT 2 NC run-time
CX1900-0102Embedded PCSpare battery suitable for CX10x0, CX50x0, CX51x0, CX90x0, CX20x0
– lithium button cell type CR2032, 3V/225 mAh
– follow polarity when installing
CX9010-N010Embedded PCInterface module for DVI/VGA+USB connection
– 2D graphics controller: min. resolution 320 x 240, max. 1280 x 1024 (Beckhoff 19" panels)
– standard DVI connector (max. 5...7 m cable length, resolution dependant)
– DVI connector includes VGA signals
  (simple adaptor connects to desktop standard CRT-VGA monitors)
– 2 x USB 2.0 ports type A
– pre-assembled ex factory, cannot be upgraded
– protection class IP 20
– operating/storage temperature: 0 °C ... +55 °C/-25 °C ... +85 °C
– weight approx. 80 g
– dimensions (W x H x D) 19 x 100 x 51 mm

自2001年3月德國倍福成立北京代表處以來,公司在中國的業(yè)務(wù)迅速發(fā)展,先后成立了上海代表處和廣州代表處。隨著各種具有良好性價(jià)比的新產(chǎn)品、新技術(shù)不斷進(jìn)入中國市場(chǎng),其勇于打破傳統(tǒng)控制模式,傾力推廣PC控制新技術(shù)的理念已被越來越多的中國用戶所接受。
總線端子

目前,通常用電纜線將 I/O 信號(hào)傳送到分布式現(xiàn)場(chǎng)總線設(shè)備或控制器上進(jìn)行集中控制。而從市場(chǎng)上采購到的來自不同廠家的現(xiàn)場(chǎng)總線設(shè)備一般具有固定的輸入/輸出配置和設(shè)計(jì),因此往往需要安裝帶有類似功能的一整套設(shè)備。這種昂貴的信號(hào)采集方法一方面會(huì)增加材料、安裝、規(guī)劃和文件制作等方面的成本,并且在后期改造或系統(tǒng)擴(kuò)展方面也會(huì)增加投入,而且還會(huì)增加庫存管理人員以及維修人員不必要的工作強(qiáng)度


靈活而穩(wěn)定

Beckhoff 總線端子是一種獨(dú)立于現(xiàn)場(chǎng)總線的開放式I/O系統(tǒng),由電子端子排組成。電子端子排的核心是帶現(xiàn)場(chǎng)總線接口的總線耦合器??偩€耦合器可用于以下總線系統(tǒng):

EtherCAT, 實(shí)時(shí)以太網(wǎng)現(xiàn)場(chǎng)總線;
Lightbus, 用于快速通訊;
PROFIBUS DP/FMS 符合 EN 50170 歐洲標(biāo)準(zhǔn);
Interbus, 于1987 年進(jìn)入市場(chǎng);
CANopen, 用于執(zhí)行器/傳感器領(lǐng)域的多主站總線;
DeviceNet, 采用 CAN 技術(shù)的設(shè)備總線;
ControlNet, 標(biāo)準(zhǔn)化現(xiàn)場(chǎng)總線;
Modbus, 開放式現(xiàn)場(chǎng)總線;
Fipio, WorldFIP 標(biāo)準(zhǔn)現(xiàn)場(chǎng)總線;
CC-Link, 適用于亞洲市場(chǎng)的現(xiàn)場(chǎng)總線
SERCOS interface, 來自驅(qū)動(dòng)工程領(lǐng)域的總線;
RS232/RS485, 的解決方案網(wǎng)絡(luò);
Ethernet TCP/IP, 網(wǎng)絡(luò)總線;
Ethernet/IP, ODVA 的工業(yè)以太網(wǎng)解決方案;
PROFINET, PROFINET,來自 PNO 的工業(yè)以太網(wǎng)解決方案;
USB, 實(shí)驗(yàn)室用快速接口。
采用主站端子,可以總線端子的形式實(shí)現(xiàn)現(xiàn)場(chǎng)總線功能。這對(duì)于在上位系統(tǒng)中集成了子系統(tǒng)的總線系統(tǒng)來說非常有益。這也就意味著子系統(tǒng)及上位總線系統(tǒng)僅需一個(gè)系統(tǒng)接口。主站端子可用于以下總線系統(tǒng):

AS-Interface, 用于下位控制級(jí)的傳感器/執(zhí)行器總線;
EIB, LON, DALI, 用于樓宇自動(dòng)化的通訊標(biāo)準(zhǔn);
 
自動(dòng)化標(biāo)準(zhǔn)

采用 Beckhoff 總線端子后,可把控制柜和安裝端子的端子盒設(shè)計(jì)得更加經(jīng)濟(jì)。通過采用 4 線制端子系統(tǒng),各種信號(hào)的傳感器和執(zhí)行機(jī)構(gòu)都可以直接連接,而無需其它連接系統(tǒng)?,F(xiàn)場(chǎng)設(shè)備無需像以往那樣在控制柜(或端子盒)與控制器之間作點(diǎn)對(duì)點(diǎn)的連接,這樣可大大減少控制器的設(shè)計(jì)成本,節(jié)約空間、材料、工程量和資金。
現(xiàn)場(chǎng)設(shè)備可以通過 Beckhoff 總線端子系統(tǒng)在產(chǎn)生信號(hào)的現(xiàn)場(chǎng)進(jìn)行連接,因此對(duì) Beckhoff 總線端子的安裝和布線就像標(biāo)準(zhǔn)端子排那樣簡易和緊湊。總線端子與控制器之間通過一個(gè)現(xiàn)場(chǎng)總線耦合器連接。
Beckhoff 總線端子已在許多領(lǐng)域得到了測(cè)試和驗(yàn)證,從機(jī)械制造到樓宇控制。采用 Beckhoff 總線端子,可使設(shè)計(jì)、基建、布線、調(diào)試安裝以及對(duì)系統(tǒng)和設(shè)備的維護(hù)和維修變得更加經(jīng)濟(jì)。
現(xiàn)場(chǎng)總線

 

上海勇控自動(dòng)化設(shè)備有限公司

上海勇控自動(dòng)化設(shè)備有限公司

工廠地址:上海市寶山區(qū)

©2024 版權(quán)所有:上海勇控自動(dòng)化設(shè)備有限公司  備案號(hào):滬ICP備17010722號(hào)-2  總訪問量:362710  站點(diǎn)地圖  技術(shù)支持:化工儀器網(wǎng)  管理登陸